ar5415p1255ea

Removing and installing fuse and relay box

Tip ar · temă 54.15 · versiune 0105 · 1996-10-08

Valabil pentru: MODEL 202.01 /02 /12 up to 30.11.94

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 2 Sistem de rulare › 54 Instalaţie electrică, echipament şi instrumente › 54.15 Cutie de siguranţe şi relee — Seria 202 (modele 01*, 02*, 12*)

EinPAS 25 Rețea de bord/Rețea/Multi-funcție › 25.20 Reţea de bord › 25.20.11 Calculator/Modul/Releu — Seria 202 (modele 01*, 02*, 12*)

EinPAS 25 Rețea de bord/Rețea/Multi-funcție › 25.20 Reţea de bord › 25.20.40 Siguranţă electrică/Diodă/Rezistenţă — Seria 202 (modele 01*, 02*, 12*)

AR54.15-P-1255EA

Removing and installing fuse and relay box

12.7.94

MODEL 202.01 /02 /12 up to 30.11.94

Removing and installing fuse and relay box

P54.15-0344-06

Fuse and relay box
Sedans up to 30.11.94

1 Fuse box cover
2 Screws
3 Relay box cover
4 Screw
6 Relay holder
7 Nuts
F1 Fuse and relay box
F1/1 Fuse box (12-fuse, in fuse and relay box F1)

F2 Maxi-fuse box (5-fuse, in fuse and relay box F1)

F3 Fuse box (18-fuse, in fuse and relay box F1)

Removal, installation

1

Disconnect ground cable at the battery

AR54.10-P-0003A

2

Remove cover of fuse box (1)

Examine gasket for signs of damage

3

Remove screws (2)

4

Remove cover of relay box (3)

Check gasket for damage

5

Unscrew screw (4)

6

Remove fuse boxes (F1/1, F2 and F3) and disconnect

7

Disconnect leads on fuse boxes or fuse blocks

Disconnect leads only when changing entire fuse and relay box. To avoid mix-ups bind disconnected leads for individual fuse boxes or blocks together and mark.

AR54.15-P-1255-01EA

Connect leads to fuse boxes or fuse blocks

AR54.15-P-1255-02EA

Fuse block assignment and lead connections

GF54.15-P-1255EB

8

Disconnect all relays

Relay holder assignment

AR54.15-P-1255-03EA

9

Remove exterior lamps failure monitoring unit

Press catch strap

10

Remove relay holder

11

Unclip connectors on bottom of relay holder or carrier

12

Remove connectors for exterior lamp failure monitoring module

AR54.15-P-1255-04EA

Install connectors for exterior lamp failure monitoring module

AR54.15-P-1255-05EA

13

Unscrew nuts (7)

14

Remove fuse and relay box (F1)

Check gasket for damage

15

Reinstall in opposite order