ar5410p0014mfa

Remove/install voltage dip limiter

Tip ar · temă 54.10 · versiune 0103 · 2020-01-21

Valabil pentru: Model 118, 177, 247

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 2 Sistem de rulare › 54 Instalaţie electrică, echipament şi instrumente › 54.10 Acumulator, alimentare cu tensiune, transformator de tensiune — Seria 118 · Seria 177 · Seria 247

EinPAS 25 Rețea de bord/Rețea/Multi-funcție › 25.20 Reţea de bord › 25.20.40 Siguranţă electrică/Diodă/Rezistenţă — Seria 118 · Seria 177 · Seria 247

AR54.10-P-0014MFA

Remove/install voltage dip limiter

20.01.2020

Model

118, 177, 247

Remove/install voltage dip limiter

P54.10-4730-09

1

Electrical connector

15

Nut

2

Pyrofuse

16

Positive terminal clamp

3

Electrical connector

17

Electrical conduction band

4

Front battery cover

18

Positive line

5

Degassing hose

G1

On-board electrical system battery

6

Screw

R62

Voltage dip limiter

14

Nut

Topical note

Notes on battery

AH54.10-P-0001-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Remove/install

1

Remove pyrofuse (2).

AR54.10-P-1180MFA

2

Release and disconnect electrical connector (1) from voltage dip limiter (R62).

3

Release, disconnect and remove electrical connector (3) from front battery cover (4).

4

Remove degassing hose (5) from on-board electrical system battery (G1).

5

Unscrew screw (6) and remove front battery cover (4).

Installation: Ensure that guides are seated correctly.

Bolt, side wall to battery frame

*BA54.10-P-1001-01D

6

Carefully bend up electrical conduction band (17).

7

Loosen nut (14) on positive terminal clamp (16) and remove positive line (18).

Nut, starter wiring harness to current limiter

*BA54.10-P-1006-01D

8

Loosen nut (15) on positive terminal clamp (16).

Nut, ground line (battery sensor) to battery terminal

*BA54.10-P-1005-01D

9

Remove voltage dip limiter (R62).

The positive terminal clamp (16) cannot be disconnected from the voltage dip limiter (R62).

10

Install in the reverse order.

Battery

Number

Designation

Model 118

Model 177

BA54.10-P-1001-01D

Bolt, side wall to battery frame

Nm

8

8

Battery

Number

Designation

Model 247

BA54.10-P-1001-01D

Bolt, side wall to battery frame

Nm

8

Battery

Number

Designation

Model 118

Model 177

BA54.10-P-1005-01D

Nut, ground line (battery sensor) to battery terminal

Nm

6

6

Battery

Number

Designation

Model 247

BA54.10-P-1005-01D

Nut, ground line (battery sensor) to battery terminal

Nm

6

Battery

Number

Designation

Model 118

Model 177

BA54.10-P-1006-01D

Nut, starter wiring harness to current limiter

Nm

16

16

Battery

Number

Designation

Model 247

BA54.10-P-1006-01D

Nut, starter wiring harness to current limiter

Nm

16

Documente menționate