1 | Radial shaft sealing ring |
S28.10-4509-06
Caution | Risk of injury to skin and eyes due to handling of transmission oil. Health risk caused by swallowing transmission oil | Wear protective gloves, protective clothing and safety glasses. | |
| Remove | ||
1 | Drain oil from transfer case. | ||
| |||
2 | Remove transfer case. | ||
3 | Remove radial shaft sealing ring (1). | | |
Dispose of radial shaft sealing ring (1). | |||
Removal and installation tool | |||
| Clean | ||
4 | Clean seat of radial shaft sealing ring (1). | Assembly cleaner | |
| Check | ||
5 | Check seating of radial shaft sealing ring (1) on transfer case. | If damage is found, | |
| |||
Perform suitable repair measures. | |||
After obtaining special order. | |||
| Install | ||
6 | Moisten sealing lips of radial shaft sealing ring (1) with transmission oil. | ||
| Automatic transmission fluids (ATF) (specification 236.12) | ||
7 | Install radial shaft sealing ring (1). | Handle | |
Drift set | |||
| Check | ||
8 | Check for correct installation position of radial shaft sealing ring (1). | If necessary, | |
| |||
Correct installation position of radial shaft sealing ring (1). | |||
Handle | |||
Drift set | |||
9 | Install transfer case. | ||
The transfer case is filled here with oil and checked for leak tightness. |
116 589 01 62 00
Removal and installation tool
470 589 12 15 00
Drift set
001 589 00 40 00
Handle
Documente menționate
- ap2800s2801p Cutie de distribuţie - schimbul uleiului
- ar2810s0100p
- as0040z000101a Pericol de rănire a pielii şi ochilor la manipularea uleiului de cutie de viteze. Pericol pentru sănătate prin înghiţire de ulei de cutie de viteze
- bb0040p023612a Uleiuri de cutii automate de viteze ATF (specificaţie 236.12)
- bb0040p023612a