ar2040t0002aa

Remove/install hydraulic pump

Tip ar · temă 20.40 · versiune 0102 · 2005-07-12

Valabil pentru: ENGINE 457.942 in MODEL NMB671.015 /020 /021 /030 /042 /332 /333

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 1 Motor › 20 Răcire motor › 20.40 Ventilator, cuplaj ventilator — Seria 671 (modele 015, 020, 021, 030, 042, 332, 333)

EinPAS 15 Motor › 15.25 Sistem răcire motor › 15.25.30 Pompă/Termostat/Dispozitiv de preîncălzire — Seria 671 (modele 015, 020, 021, 030, 042, 332, 333)

Valabil și pentru motoare/cutii de viteze: 457 942

AR20.40-T-0002AA

Remove/install hydraulic pump

6.6.01

ENGINE 457.942 in MODEL NMB671.015 /020 /021 /030 /042 /332 /333

Remove/install hydraulic pump

T20.40-0008-01

Shown on model 671.042

1 Feed line

2 Return flow pipe

3 Spacer

4 Hydraulic pump

Remove/Install

1

Open rear lid

Danger!

Risk of injury to skin or eyes caused by hydraulic fluid spraying out under pressure. Risk of poisoning caused by swallowing hydraulic fluid.

Depressurize the hydraulic system completely before starting any work on the system. Wear protective clothing and safety glasses.

AS00.00-Z-0013-01A

2

Drain hydraulic fluid

Hydrostatic fan drive - oil and filter change

AP20.40-T-2001AA

3

Detach the feed line (1) and the return line (2) from the space (3) and from the hydraulic pump (4)

Collect hydraulic oil which flows out in a suitable vessel.

Installation: Install new sealing rings.

4

Detach the hydraulic pump (4) from the engine housing

Installation: Install new gasket

5

Remove the hydraulic pump (4) from the engine housing

6

Install in the reverse order

Danger!

Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns when working in engine during starting procedure

Secure vehicle to prevent it from moving off by itself.
Wear closed and snug-fitting work clothes.
Do not grasp hot or rotating parts.

AS00.00-Z-0005-01A

7

Crank the engine and run it in the neutral

Check

8

Check the mounting flange as well as the feed line (1) and return line (2) connections at the hydraulic pump (4) for leaks

Documente menționate