T15.30-0001-11
12 Electric cables of starter
| Removing, installing | ||
1 | Switch off ignition | ||
2 | Open service flap on left ahead of rear axle | Release battery tray and pull out. | |
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
3 | Disconnect ground at battery | First of all disconnect negative terminal. Ensure that there is no risk of unintentional contact between ground cable and negative terminal of battery. | |
| Notes on battery | all models | |
4 | Remove engine compartment encapsulation below starter | ||
5 | Separate electric cables of starter (12) | ||
6 | Unscrew nuts of starter at crankcase (arrow) | Take starter out of crankcase. | |
| |||
| |||
7 | Install in the reverse order |
Starter
Torque wrench
000 589 64 21 00
Documente menționate
- ah5410p000101a Indicaţii pentru acumulator
- ah5410p000101a
- as5410z000101a Pericol de incendiu/explozie, ca urmare a scurtcircuitului și a gazului detonant evacuat. Pericol de combustie/pericol de rănire, ca urmare a iritării ochilor, a pielii şi a mucoasei, ca urmare a electrolitului de acumulator/vaporilor