ar1440b2050a

Remove/install sieve on metering device compressed air inlet for EATS

Tip ar · temă 14.40 · versiune 0201 · 2019-11-15

Valabil pentru: Engine 924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2 Engine 926.9 in model 368, 382.17/18, 384.0

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 1 Motor › 14 Galerie de evacuare, frână motor, instalaţie de purificare a gazelor arse › 14.40 Purificare a gazelor arse, AdBlue — Seria 368 · Seria 382 (modele 17*, 18*) · Seria 384 (modele 0**, 2**) · Seria 685 (modele 282, 284, 289, 290) · Seria 979 (modele 2**)

EinPAS 15 Motor › 15.40 Instalaţie gaze arse/purificare a gazelor arse › 15.40.51 Pompă/Dozator/Duză — Seria 368 · Seria 382 (modele 17*, 18*) · Seria 384 (modele 0**, 2**) · Seria 685 (modele 282, 284, 289, 290) · Seria 979 (modele 2**)

Valabil și pentru motoare/cutii de viteze: 924 9**, 926 9**

AR14.40-B-2050A

Remove/install sieve on metering device compressed air inlet for EATS

01.11.2019

Engine

924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2

Engine

926.9 in model 368, 382.17/18, 384.0

Remove/install sieve on metering device compressed air inlet for EATS

W14.40-1519-09

1

Metering unit

3

Strainer

5

Compressed air inlet

2

Compressed air piping

4

Screwdriver

Remove/install

1

Open the engine access cover

2

Remove the compressed air piping (2) at the metering device (1)

Plug the hole with a suitable sealant.

Wait until the pressure is released before starting any work on the exhaust gases treatment system.

Installation: Before mounting, inspect the compressed air tubing connection (2) for impurities, contaminants and damage.

.Compressed air line hollow bolt on dosage unit

*BA14.40-B-1033-02B

3

Remove the filter (3) using a screwdriver (4)

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

4

Install in reverse order.

5

Start the engine

6

Check the tightness of the dosing unit (1) with the engine running

Exhaust gas after-treatment

Number

Designation

Engine 924.9, 926.9 except Liquid Only

BA14.40-B-1033-02B

Compressed air line hollow bolt on dosage unit

Nm

15