Remove/install check valve at air controller unit of exhaust aftertreatment system

Tip ar · temă 14.40 · versiune 0301 · 2019-11-19

Valabil pentru: Engine 924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2 Engine 926.9 in model 368, 382.17/18, 384.0

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 1 Motor › 14 Galerie de evacuare, frână motor, instalaţie de purificare a gazelor arse › 14.40 Purificare a gazelor arse, AdBlue — Seria 368 · Seria 382 (modele 17*, 18*) · Seria 384 (modele 0**, 2**) · Seria 685 (modele 282, 284, 289, 290) · Seria 979 (modele 2**)

EinPAS 15 Motor › 15.40 Instalaţie gaze arse/purificare a gazelor arse › 15.40.13 Conductă/Furtun/Supapă — Seria 368 · Seria 382 (modele 17*, 18*) · Seria 384 (modele 0**, 2**) · Seria 685 (modele 282, 284, 289, 290) · Seria 979 (modele 2**)

Valabil și pentru motoare/cutii de viteze: 924 9**, 926 9**

AR14.40-B-2032A

Remove/install check valve at air controller unit of exhaust aftertreatment system

31.10.2019

Engine

924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2

Engine

926.9 in model 368, 382.17/18, 384.0

Remove/install check valve at air controller unit of exhaust aftertreatment     
	system

Represented in vehicle 382.177

1

Compressed air inlet

2

Compressed air outlet

3

Connection bolt

4

Connection bolt

5

Check valve (8.01)

6

Pressure regulating valve (33.03)

B14.40-0075-11

Remove/install

1

Remove the pressure regulating valve (33.03) (6)

Remove/install pressure limiting valve at air controller unit of the exhaust aftertreatment system
.

AR14.40-B-2016A

Topical note

Notes on self-locking nuts and bolts

AH00.00-N-0001-01A

Notes on compressed air connection systems

AH00.18-N-0001-01A

2

Loosen the connection bolt (4) from the compressed air inlet (1)

After shutting the engine down, the compressed air continues to flow through some compressed air lines for approximately 3 min. For this reason, start working on the compressed air control unit, after this time has elapsed.

Firstly, slacken the connection screw (4) in two turns to release the pressure of the system and then remove it completely.

.Compressed air connection system "VOSS 232"

*BA00.18-B-1002-01A

3

Loosen the connection bolt (3) from the compressed air outlet (2)

Firstly, slacken the connection bolt (3) by two turns to let the pressure out of the system, then remove it completely.

.Compressed air connection system "VOSS 232"

*BA00.18-B-1002-01A

4

Remove the check valve (8.01) (5)

5

Installation in reverse order

6

Charge the compressed air system up to the limiting pressure

Compressed air piping

Number

Designation

Model all (BUS, TRUCK)

BA00.18-B-1002-01A

Compressed air connection system "VOSS 232"

M16

Nm

14

M14

Nm

14

M22

Nm

14