ap8300d8381a

Replace dust filter for heating/air conditioning

Tip ap · temă 83.00 · versiune 0107 · 2011-08-29

Valabil pentru: MODEL 901, 902, 903, 904, 905 with CODE (H06) Air conditioning with CODE (H25) "Heatmatic" automatic heater control with CODE (H81) Ventilation system with filter with CODE (HH9) Regulated air conditioning (Tempmatic) MODEL 690.6 with CODE (H81) Ventilation system with filter with CODE (HH9) Regulated air conditioning (Tempmatic) MODEL WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (H06) Air conditioning with CODE (H81) Ventilation system with f

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 3 Suprastructură › 83 Climatizare › 83.00 Generalităţi — Seria 690 (modele 6**) · Seria 901 · Seria 902 · Seria 903 · Seria 904 · Seria 905

EinPAS 39 Încălzire/Aerisire/Răcire › 39.15 Climatizare › 39.15.32 Carcasă/Schimbător de căldură/Vaporizator/Filtru — Seria 690 (modele 6**) · Seria 901 · Seria 902 · Seria 903 · Seria 904 · Seria 905

AP83.00-D-8381A

Replace dust filter for heating/air conditioning

23.8.11

MODEL 901, 902, 903, 904, 905
with CODE (H06) Air conditioning
with CODE (H25) "Heatmatic" automatic heater control
with CODE (H81) Ventilation system with filter
with CODE (HH9) Regulated air conditioning (Tempmatic)

MODEL 690.6
with CODE (H81) Ventilation system with filter
with CODE (HH9) Regulated air conditioning (Tempmatic)

MODEL WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7
with CODE (H06) Air conditioning
with CODE (H81) Ventilation system with filter
with CODE (HH9) Regulated air conditioning (Tempmatic)

Replace dust filter for heating/air conditioning
Replace dust filter for heating/air conditioning

N83.00-2132-01

N83.00-2131-01

Remove/install

1

Remove insulation above ventilation box
lid (1)

2

Open the locking clips (2) at the front and the back

Installation: Ensure that the locking clips are tightened enough.

3

Slide ventilation box lid in direction of arrow and remove

4

Remove dust filter (3)

Installation: Install dust filter/combination filter corresponding to the code version.

5

Install in the reverse order