gf9130p2005a

Ventilation Mode Function

Tipo gf · tema 91.30 · versão 0101 · 2001-03-06

Válido para: MODEL 210 as of 1.7.99 up to 31.5.01, 210 as of 1.6.01 with CODE (401a) Seat ventilation of front seats

Não disponível em “pt”; apresentado em Inglês.

Onde se situa

Grupo funcional 3 Carroçaria › 91 Assentos, leitos, sistemas de retenção › 91.30 Aquecimento do assento, ventilação do assento — Série 210

GF91.30-P-2005A

Ventilation Mode Function

2.2.99

MODEL 210 as of 1.7.99 up to 31.5.01,
210 as of 1.6.01 with CODE (401a) Seat ventilation of front seats

Function prerequisites:

Terminal 15R or terminal 15 ON

there is no shutdown on faults for the control module

The ventilation mode has three stages:

The motor speed,

1 slow

2 medium

3 fast

is switched on/off and changed using the switch for HS and seat ventilation, front left (N25/7s1) and the switch for HS and seat ventilation, front right (N25/7s2) in the control module for HS and seat ventilation, front (N25/7).

Up to 31.05.01 with code (401a) seat ventilation for front seats

The ventilation mode is, if there are no faults,

started at stage 3, switched back automatically after 10 min to stage 2 and after an additional 10 min to stage 1.

It is possible to switch off or change the seat ventilation to another ventilation stage at any time by means of the switch.

As of 01.06.01 with code (401a) seat ventilation for front seats,

the timer control of the ventilation mode for front seats is discontinued.

The selected ventilation stage (I, II, III) of the seat ventilation remains switched on and is not switched back automatically.

It is possible to switch off or change the seat ventilation to another ventilation stage at any time by means of the switch.

Timer control of seat ventilation up to 31.05.01

I Ventilation stage I

I Ventilation stage II

I Ventilation stage III

5

20

10

25

15

I

II

III

t

min

P

0

Operation of seat ventilation via switch:

Switch actuation

N25/7s1

N25/7s2

Operating condition of seat ventilation

after actuating switch

Function indicator lamp (LED)

Off position

OFF

none

pressed 1 x

Ventilation stage III

LED 1, 2, 3

pressed 2 x

Ventilation stage II

LED 1, 2

pressed 3 x

Ventilation stage I

LED 1

pressed 4 x

OFF

none

pressed 5 x

Ventilation stage III

LED 1, 2, 3

End ventilation mode function

GF91.30-P-2006A

Shutdown on faults for control module function

GF91.30-P-2007A

Switch for heated seats/seat ventilation - location/task

GF91.30-P-3004A

Control module for heated seats and seat ventilation - location/task

GF91.30-P-3005A

Documentos referenciados