P77.30-2022-09
The individual stages when closing the soft top
Soft top open.
Stage 1
Keep pressing the soft-top operation switch (S84). The soft-top operation indicator lamp and status display (S84e1) in the soft-top operation switch (S84) starts to flash on and off (until the end of stage 11).
As long as the soft-top operation switch (S84) is pressed or the CAN message "SOFT TOP UNLOCKED" is present, no remote trunk release is possible.
For safety reasons the closing procedure is interrupted immediately at any time (stop function) if the soft-top operation switch (S84) is released.
Stage 2
The side windows at the front and rear are opened electrically. The roll bar is lowered hydraulically.
-------------------------------------------------------------------------------------------
Stage 3
The soft top compartment cover is unlocked hydraulically.
Stage 4
The soft top compartment cover is pivoted up hydraulically.
Stage 5
The soft top is moved hydraulically out of the soft-top compartment. The roll bar (RB)/ soft-top operation control module (N52) cancels the bridge for the temperature sensor (B10/4b1) of the air conditioning again.
Stage 6
The soft top bow is pivoted up hydraulically until in an approximately 90° position.
Stage 7
The soft top compartment cover is pivoted downward hydraulically.
-------------------------------------------------------------------------------------------
Stage 8
The soft top compartment cover is locked hydraulically.
Stage 9
The soft top bow is pivoted downward hydraulically.
Stage 10
The soft top bow is locked hydraulically. A signal sounds from the overhead control panel control module (N70), the manual locking of the soft top can now be started (see stage 11).
Stage 11
Manually: Turn the release lever to the right and pull the soft top toward the window frames.
Then turn the release lever to the left and fold up.
The roll bar is raised (if not raised beforehand) and the side windows at the front and rear are closed (if not raised beforehand). The soft-top operation indicator lamp and status display (S84e1) in the soft-top switch (S84) goes out.
Top-up times
Even after the individual limit switch positions have been reached, the corresponding hydraulic cylinder still remains actuated for a short time to compensate for tolerances of the limit switch switching points.
Soft-top operation interruption, function | |||
Soft top hydraulic system, function | |||
Roll bar (RB), function | |||
Roll bar/soft-top operation hydraulic unit, location/task/design/function | |||
Soft-top operation switch, location/task/design/function | |||
Soft top compartment cover open limit switch, location/task/design/function | |||
Soft top open/closed switch train, location/task/design/function | |||
Soft top locked limit switch, left, location/task/design/function | |||
Trunk cover closed limit switch, location/task/design/function | |||
Soft top bow bottom/top limit switch, location/task/design/function | |||
Soft top bow locked limit switch, location/task/design/function |