GF77.30-P-2003KA | Close soft top, function | 4.2.98 |
MODELS 208.435,
208.444 up to 19.11.00,
208.445 /447,
208.448 /465 /470 up to 19.11.00
P77.30-2022-09
The individual stages when closing the soft top
Stage 0
Soft top open.
Stage 1
Keep pressing the soft-top operation switch (S84). The indicator lamp in the soft-top operation switch (S84) starts to flash on and off (until end of stage 11).
For safety reasons the closing procedure is interrupted immediately at any time (stop function) if the soft-top operation switch (S84) is released.
Stage 2
The side windows at the front and rear are opened electrically (if closed beforehand). The roll bar is lowered hydraulically (if raised beforehand).
-------------------------------------------------------------------------------------------
Stage 3
The soft top compartment cover is unlocked hydraulically.
Stage 4
The soft top compartment cover is pivoted up hydraulically.
Stage 5
The soft top is moved hydraulically out of the soft-top compartment. The roll bar (RB)/ soft-top operation control module (N52) cancels the bridge for the temperature sensor (B10/4b1) of the air conditioning again.
Stage 6
The soft top bow is pivoted up hydraulically until in an approximately 90° position.
-------------------------------------------------------------------------------------------
Stage 7
The soft top compartment cover is pivoted downward hydraulically.
Stage 8
The soft top compartment cover is locked hydraulically.
Stage 9
The soft top bow is pivoted downward hydraulically.
Stage 10
The soft top bow is locked hydraulically. A signal sounds from the overhead control panel control module (N70), the manual locking of the soft top can now be started (see stage 11).
Stage 11
Manually: Turn the release lever to the right and pull
the soft top toward the window frames.
Then turn the release lever to the left and fold up.
Stage 12
The roll bar is raised (if not raised beforehand) and the side windows at the front and rear are closed (if not closed beforehand).
The indicator lamp in the soft-top operation switch (S84) goes out.
Top-up times
Even after the individual limit switch positions have been reached, the corresponding hydraulic cylinder still remains actuated for a short time to compensate for tolerances of the limit switch switching points.
Open soft top, function | |||
Soft-top operation interruption, function | |||
Soft-top hydraulics, function | |||
Roll bar (RB), function | |||
Roll bar/soft-top operation hydraulic unit, location/task/design/function | |||
Soft-top operation switch, location/task/design/function | |||
Soft top compartment cover switch train, location/task/design/function | |||
Soft top compartment cover open limit switch, location/task/design/function | |||
Soft top open/closed switch train, location/task/design/function | |||
Soft top locked limit switch, left, location/task/design/function | |||
Trunk cover closed limit switch, location/task/design/function | |||
Soft top bow bottom/top limit switch, location/task/design/function | |||
Soft top bow locked limit switch, location/task/design/function |