ar8610p0104a

Remove/install extinguishing agent tank squib

Tipo ar · tema 86.10 · versão 0102 · 2009-05-26

Válido para: MODEL 463.236 /236 with CODE (979) Special protection version with CODE (ZS6) Special protection version FB6 with fire extinguishing system MODEL 463.248 /248 with CODE (979) Special protection version with CODE (ZS7) Special protection version FB7 with fire extinguishing system

Não disponível em “pt”; apresentado em Inglês.

Onde se situa

Grupo funcional 3 Carroçaria › 86 Aparelhos de emergência, equipamento especial para deficiente físico, equipamento sanitário, cozinha › 86.10 Equipamentos de emergência — Série 463 (modelos 236, 248)

EinPAS 27 Sistemas de segurança/de segurança do ocupante do veículo passivos › 27.21 Sistema de extinção de incêndio/sistema de alerta de incêndio › 27.21.50 Reservatório — Série 463 (modelos 236, 248)

AR86.10-P-0104A

Remove/install extinguishing agent tank squib

30.4.09

MODEL 463.236 /236
with CODE (979) Special protection version
with CODE (ZS6) Special protection version FB6
with fire extinguishing system

MODEL 463.248 /248
with CODE (979) Special protection version
with CODE (ZS7) Special protection version FB7
with fire extinguishing system

Remove/install extinguishing agent tank squib

P86.10-2105-11

Shown on extinguishing agent tank, left side

1 Extinguishing agent tank 1

R42 Extinguishing agent reservoir squib 1

R42x1 Extinguishing agent tank 1 squib electrical connector

Remove/install

Notes on squib on extinguishing agent tank

AH86.10-P-0001-04A

1

Switch off ignition

2

Remove extinguishing agent tank cover

AR86.10-P-0103A

3

Disconnect electrical connector on extinguishing agent tank 1 squib (R42x1) or electrical connector on extinguishing agent tank 2 squib (R42/1x1)

When working on squibs always wear eye protection to avoid eye injuries.

To prevent the fire extinguishing system from being actuated, first disconnect electrical connector from extinguishing agent tank 1 squib (R42x1) or electrical connector from extinguishing agent tank 2 squib (R42/1x1) as first operation step.

4

Remove extinguishing agent tank 1 squib (R42) from extinguishing agent tank 1 (1) or extinguishing agent tank 2 squib (R42/1) from extinguishing agent tank 2

When working on squibs always wear eye protection to avoid eye injuries.

Installation: Secure nuts with locking plates to prevent unscrewing by themselves.

*BA86.10-P-1006-01A

5

Install in the reverse order

Checking

6

Check extinguishing agent tank 1 squib (R42) or extinguishing agent tank 2 squib (R42/1)

When working on squibs always wear eye protection to avoid eye injuries.

AR86.10-P-0121A

Fire extinguishing system

Number

Designation

Model
463.236/248 with
code 979 and
fire extinguishing system

BA86.10-P-1006-01A

Nut, housing on squib to extinguishing agent tank

Nm

10

Documentos referenciados