Commercially available tools
Number | Designation | |
WH58.30-Z-1003-02A | Clamping pliers | |
WH58.30-Z-1031-02A | C-clamp | |
WH58.30-Z-1001-03A | Round wire brush, braided, dia. 70 mm | |
WH58.30-Z-1024-04A | Abrasive disk, dia. 115 mm, 80 m/s (max. 13,250 rpm) | |
WH58.30-Z-1001-40A | Tarp (fire-resistant) |
Workshop equipment
WE58.40-Z-1001-02A | Inert gas welder |
WE58.40-Z-1001-03A | Drill (electric/pneumatic) |
WE58.40-Z-1002-03A | Straight grinder (electric/pneumatic) |
WE58.40-Z-1003-03A | Angle grinder (electric/pneumatic) |
WE58.40-Z-1005-03A | Wet/dry vacuum cleaner |
P63.30-2430-08
1 Install outer main floor panel reinforcement (1) with outer firewall bottom section and fit.
2 Fasten outer main floor panel reinforcement (1) to body with clamping pliers and C-clamps.
3 Weld in outer main floor panel reinforcement (1) in areas A to C with .
Complete spot weld in area D only in combination with bottom of firewall
P63.30-2431-08
4 Weld in outer main floor panel reinforcement (1) in area E with .
5 Clean all spot welds with wire brush