P63.20-6129-06
1 Expose spot welds in areas A to E on C-pillar paneling (1) and cut out.
P63.20-6130-12
2 Expose spot welds in areas F and G on C-pillar paneling (1) and cut out.
P63.20-6131-06
3 Expose spot welds in areas H and J on C-pillar paneling (1) and cut out.
P63.20-6132-11
4 Loosen glue joint of C-pillar paneling (1) in marked area (dotted line).
P63.20-6175-05
5 Cut in areas K and L on C-pillar paneling (1) along lines.
Do not damage reinforcements or sheet metal panels below.
6 Remove C-pillar paneling (1).