N60.00-2179-09
Illustrated on model 639.601
1 Insulation on upper right side wall paneling
Dimension a approx. 200 mm
Dimension b approx. 200 mm
2 Insulation on lower right side wall paneling
Dimension a approx. 65 mm
Dimension b approx. 130 mm
3 Insulation on lower right side wall paneling
Dimension a approx. 290 mm
Dimension b approx. 100 mm
4 Insulation on lower right side wall paneling
Dimension a approx. 160 mm
Dimension b approx. 150 mm
1 Remove damaged insulation from right side wall paneling.
2 Clean right side wall paneling in area of bonding surfaces for vapor barriers.
3 Cut new insulation to required dimensions.
4 Install new insulation on right side wall paneling.
Observe manufacturer's specification when processing vapor barriers. Insulation on right upper side wall paneling (1) are eliminated on vehicles with windows.