ar4110p008509rt

Measure the absolute angle at the flange of the transfer case

Tipo ar · tema 41.10 · versão 0100 · 2006-07-26

Válido para: MODEL 251

Não disponível em “pt”; apresentado em Inglês.

Onde se situa

Grupo funcional 2 Chassí › 41 Árvore de transmissão articulada › 41.10 Árvore de transmissão articulada — Série 251

EinPAS 17 Trem de força/eixo › 17.40 Árvore de transmissão › 17.40.30 Árvore de transmissão da tração/tração total — Série 251

AR41.10-P-0085-09RT

Measure the absolute angle at the flange of the transfer case

Data Sheet for Measuring Inclination Angle, Form

OF41.10-P-3000-01B

Workshop equipment

WE58.40-Z-1002-15A

Electronic clinometer

WE58.40-Z-1003-15A

Electronic propeller shaft inclinometer

WE58.40-Z-1004-15A

Electronic combination measuring instrument

Measure the absolute angle at the flange of the transfer case

P41.10-2269-09

3a Absolute angle at front flange of transfer case

3b Absolute angle at rear flange of transfer case

Measure the absolute angle at the flange of the transfer case

P41.10-2289-09

Measurement of absolute angle 3a at front flange of transfer case

086a Sensor

8a Adapter for transmission

10 Cable

12 Front flange on transfer case

1 Attach the adapter for transmission (8a) to the front flange on the transfer case (12) and move into the horizontal position using the spirit level.

The absolute angle at the front flange of the transfer case (3a) and the absolute angle at the rear flange of the transfer case (3b) have the same value. The absolute angle at the front flange of the transfer case (3a) is measured here.

Check seat of the magnetic fork at the front flange on the transfer case (12).

If the position of the sensor (086a) deviates too much from the horizontal, a fault message appears on the measuring instrument display, no value can be read off or stored.

2 Place the sensor (086a) on the support plate.

-----------------------------------------------------------------------------------------

The cable (10) must point in the direction of travel (arrow), otherwise an incorrect measurement will occur.

Ensure that the sensor (086a) is seated correctly in the bores of the support plate, otherwise an incorrect measurement will occur.

3.1 Read off absolute angle at the front flange of the transfer case (3) on the measuring instrument display and enter in the data sheet.

If the electronic inclinometer is used or if measurements are made in inclination measuring mode with the electronic articulation/propeller shaft inclinometer

The X-value must be read off on the display. Otherwise incorrect measurement results occur.

The measured value must not be stored.

-----------------------------------------------------------------------------------------

The absolute angle at the front flange of the transfer case (3) may only be read off if the sensor (086a) is on standby and the displayed value is constant.

3.2 Store the absolute angle at the front flange of the transfer case (3) in the measuring instrument.

If the electronic propeller shaft inclinometer with memory extension or the electronic articulation/propeller shaft inclinometer with memory extension is used in articulation angle measuring mode.

Save the measured value by pressing the SAVE button. After this the measurement readiness for the fourth angle is displayed.

The absolute angle at the front flange of the transfer case (3) may only be stored if the sensor (086a) is on standby and the displayed value is constant.

Documentos referenciados