S09.20-4506-06
1 Hose
2 Centrifuge
3 Air duct housing
4 Locks
5 Clamp
6 CLIC clamp
7 Gasket
| Remove/install | ||
1 | Remove hot film mass air flow sensor | ||
2 | Detach hose (1) on centrifuge (2) | ||
3 | Remove air guide housing (3) | To do this unlock locks (4) and pull air guide housing (3) to the rear. | |
4 | Remove air guide housing (3) | To do this, remove clamp (5). | |
5 | Remove hose (1) | Only when replacing the air duct housing (3). | |
Installation: do not use any screw clamps or clamps. The hose (1) must be fixed in place with the new CLIC clamp (6) to avoid leaks. | |||
6 | Check seal (7), replace if necessary. | ||
7 | Install in the reverse order |