AN54.18-G-0004B | Retrofit wiring harness for Electronic Quick Reverse (EQR) | 14.2.12 |
MODEL 405.100 /102 /120 /122 /200 /220 ## up to 201606
G54.21-3285-09
1 Cover
2 Cover
3 Cover
4 Switch panel
5 Cover
6 Center console
A7 Base module (central electrics)
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect battery ground line | ||
| Notes on battery | All models | |
2 | Remove covers (1, 2) from electrical compartment and stowage compartment | ||
3 | Release base module (electrical center) (A7) and fold forwards | ||
4 | Remove cover (3) of switch panel (4) | ||
5 | Remove covers (5) of center console (6) | ||
6 | Remove screws for center console (6) at front and rear and tilt center console (6) to one side | ||
7 | Retrofit wiring harness for Electronic Quick Reverse (EQR) into cab | ||
8 | Install in the reverse order | ||
9 | Check electrical system for proper operation |
Documentos referenciados
- ah5410p000101a Indicações da bateria
- ah5410p000101a
- an5418g000401b
- as5410z000101a Risco de incêndio/explosão através de curto-circuito e vazamento de gás oxídrico. Risco de combustão/lesão por cauterização dos olhos, pele e mucosas através de eletrólito/névoa da bateria, curto-circuito e arco elétrico. Risc