S91.60-4641-09
1 | Driver kneebag | 4 | Connector socket | |
2 | Bolts | 4.1 | Fuse | |
3 | Bracket |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on carrying out repair work in the vehicle interior | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Disconnect battery ground line | ||
2 | Remove bottom paneling for dashboard on driver side | ||
3 | Remove screws (2) | Installation: Ensure that the brackets (3) do not turn when tightening the screws/bolts (2). | |
Bolt, knee airbag to crossmember for instrument panel | |||
4 | Unhook brackets (3) upwards and remove | ||
5 | Unhook driver knee airbag (1) upward out of brackets of crossmember | ||
6 | Unlock fuse (4.1) using a suitable tool | ||
7 | Remove connector socket (4) from driver knee airbag (1) and remove driver knee airbag (1) from vehicle | ||
8 | Install in the reverse order | ||
| Check | ||
9 | Check Supplemental Restraint System (SRS) with diagnostic system | ||
|
Powiązane dokumenty
- ad0000s200006p
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah6800n000101s Wskazówki dotyczące wykonywania prac naprawczych we wnętrzu pojazdu
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar5410s0003p
- ar6810s1501p
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi