P91.60-2656-09
1 | Bolts | 2 | Electrical connector | 3 | Sidebag unit |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m) | ||
2 | Disconnect battery ground line | ||
3 | Remove left or right side paneling in rear | ||
4 | Remove bolt (1) | Bolt for sidebag unit | |
5 | Release and disconnect electrical connection (2) | ||
6 | Remove sidebag unit (3) | ||
7 | Install in the reverse order | ||
| Check | ||
8 | Check and erase vehicle fault memory using diagnostic system | When replacing sidebag unit (3). | |
|
Powiązane dokumenty
- ad0000p200004a Podłączanie STAR DIAGNOSIS, odczytywanie pamięci usterek
- ad0000p200004a
- ah0000n000101a Wskazówki dotyczące samozabezpieczających śrub i nakrętek
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar5410p0003q
- ar6830p4780qa
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi