1 | Riveting |
2 | Sidebag unit |
P91.60-5112-06
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Switch off ignition and remove transmitter key | ||
2 | Disconnect battery ground line | ||
3 | Remove door lining from left or right front door |
| |
4 | Drill out rivets (1) of sidebag unit | ||
5 | Remove sidebag unit (2) | ||
6 | Release and disconnect electrical connection | ||
7 | Install in the reverse order | ||
| Check | ||
8 | Check and erase vehicle fault memory using diagnostic system | When replacing sidebag unit (2). | |
|