1 | Passenger side paneling |
2 | Front passenger airbag unit |
3 | Electrical connector |
4 | Screw |
5 | Nut |
P91.60-3457-06
| Remove/install | ||
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | |
Topical note | Notes on performing repair, body work and welding on vehicles with airbags and RTE units | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Legal requirements on handling and storing airbags and emergency tensioning retractor units | |||
1 | Disconnect ground line of battery | ||
2 | Remove front passenger side trim (1) | ||
3 | Disconnect electrical connector (3) at front passenger airbag unit (2) | ||
4 | Remove screws (4) of front passenger airbag unit (2) | On vehicles as of 31.8.10, a wiring harness is fixed in place at the left bracket of the front passenger airbag unit (2) above the screw (4). It must be released before removing the front passenger airbag unit (2). | |
Bolt, front passenger airbag unit to instrument panel support | |||
5 | Unscrew nuts (5) of front passenger airbag unit (2) and remove front passenger airbag unit (2) downwards | | |
Installation: Observe tightening sequence (A to D) of the nuts (5). | |||
Nut, front passenger airbag unit to instrument panel | |||
6 | Install in the reverse order | ||
7 | Check supplemental restraint system using STAR DIAGNOSIS | When replacing the front passenger airbag unit (2). | |
|
Powiązane dokumenty
- ad0000p200004mcc
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah9100p000201m Wskazówki dotyczące prac naprawczych, napraw nadwozia i prac spawalniczych w pojazdach wyposażonych w zespoły poduszki powietrznej i napinaczy pasów bezpieczeństwa
- ah9100p000401a Przepisy prawa regulujące obchodzenie się i składowanie zespołów poduszek powietrznych i napinaczy pasów bezpieczeństwa
- ar5410p0003mcc Odłączanie, podłączanie przewodu masowego akumulatora
- ar6810p1502mcc
- as9100z000101a Niebezpieczeństwo obrażeń podczas czynności diagnostycznych i naprawczych przy zespołach poduszki powietrznej i napinaczy pasów bezpieczeństwa.