P91.60-A008-08
1 | Electrical connectors | 4 | Nuts | |
2 | Ground clip | 5 | Passenger airbag | |
3 | Screw | 6 | Guide |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on self-locking nuts and bolts | ||
Notes on safety-relevant components | |||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Clamp off ground line of on-board electrical system battery (G1). | ||
2 | Remove glove box. | ||
3 | Release and disconnect electrical connections (1). | Installation: Ensure that the catch mechanism engages audibly. | |
Removal lever | |||
4 | Remove ground clip (2). | Bolt, ground connection of front passenger airbag to crossmember below instrument panel | |
5 | Remove screw/bolts (3). | Bolt, front passenger airbag unit to instrument panel | |
6 | Unscrew nuts (4). | Nut, front passenger airbag unit to instrument panel | |
7 | Remove front passenger airbag (5). | Installation: Insert front passenger airbag (5) into guide (6). | |
8 | Install in the reverse order. | ||
| Check | ||
9 | Check Supplemental Restraint System (SRS) using vehicle diagnosis system. | When replacing the front passenger airbag (5). | |
|
203 589 04 33 00
Removal lever
Powiązane dokumenty
- ad0000p200006mfa
- ah0000n000101a Wskazówki dotyczące samozabezpieczających śrub i nakrętek
- ah0000z001901a Wskazówki dotyczące elementów wpływających na bezpieczeństwo
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar5410p0003mfa
- ar6810p1400mfa
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi