P91.60-4839-07
1 | Glove compartment | 3 | Bolts | |
2 | Front passenger kneebag |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Notes on working in engine compartment | ||
Topical note | Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | ||
| Remove/install | ||
1 | Open engine hood | ||
2 | Disconnect battery ground line | ||
3 | Remove glove compartment (1) | ||
4 | Disconnect electrical connector from front passenger kneebag squib | Installation: The electrical connector at the front passenger kneebag squib must audibly engage when attached. | |
5 | Remove bolts (3) | Bolt, front passenger airbag to bracket | |
6 | Remove front passenger kneebag (2) towards left from glove compartment | ||
7 | Install in the reverse order | ||
| Check | ||
8 | Check supplemental restraint system (SRS) using STAR DIAGNOSIS | After replacing front passenger kneebag (1). | |
9 | Connect STAR DIAGNOSIS, read out fault memory | ||
|
Powiązane dokumenty
- ad0000p200004b Podłączanie STAR DIAGNOSIS, odczytywanie pamięci usterek
- ah6000p004201rg Wskazówki dotyczące prac w komorze silnika
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar5410p0003rg
- ar6810p1400rg
- ar8840p1000rg
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi