1 | Gas shut-off cock |
2 | Union nut |
3 | Screw |
4 | Screw |
5 | Ground cable |
S86.60-4631-11
Danger ! | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
| Notes on carrying out repair work in the vehicle interior | ||
| Remove/install | ||
1 | Close shutoff valve on gas cylinder | See owner's manual. | |
2 | Remove paneling from kitchenette below cover of refrigerator box | ||
3 | Close gas shut-off cock (1) | ||
4 | Unscrew union nuts (2). | ||
5 | Unscrew bolt (4) | ||
6 | Unscrew nut from bolt (3) and remove ground line (5) | Installation: Ensure that assembly position for ground line (5) is correct. | |
7 | Unscrew bolt (3) and remove shut-off cock (1) | ||
8 | Install in the reverse order | ||
| Check | ||
9 | Check gas system for proper function and leakage |
Powiązane dokumenty
- ah6800n000101s Wskazówki dotyczące wykonywania prac naprawczych we wnętrzu pojazdu
- ar8661s2283e
- as0000z001801a Niebezpieczeństwo wybuchu wskutek ulatniania się palnych gazów lub przegrzania zbiorników gazu. Niebezpieczeństwo obrażeń wskutek oparzeń oczu i skóry. Niebezpieczeństwo odmrożeń wskutek gwałtownego rozprężania się gazu ora