P86.10-2439-09
Shown on model 177.0 with code 2U8 (Alternative refrigerant) |
1 | Inerting system cartridge | 4 | Retaining clamp | |
2 | Mounting clip | 5 | Line | |
3 | Electrical connector | 6 | Nuts |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on safety-relevant components | |||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Remove cover for air/water duct. |
| |
Model 247 with engine 260, 282 | |||
2 | Detach ground line of on-board electrical system battery. | ||
3 | Unclip retaining clip (2). | Dismantling tool | |
4 | Release and disconnect electrical connection (3). | Removal lever | |
5 | Remove retaining clamp (4) and disconnect line (5) from inerting system cartridge (1). | Installation: Always replace retaining clamp (4). | |
6 | Remove nuts (6). | Nut, inerting system cartridge to body | |
7 | Remove inerting system cartridge (1). | ||
8 | Check seal on connection of line (5) to inerting system cartridge (1) for damage. | If damage is present, | |
| |||
replace inerting system cartridge (1). | |||
9 | Install in the reverse order. |
000 589 95 63 00
Dismantling tool
203 589 04 33 00
Removal lever
Powiązane dokumenty
- ah0000z001901a Wskazówki dotyczące elementów wpływających na bezpieczeństwo
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar5410p0003mfa
- ar8310p1411mfa
- ar8310p1411mfb
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi