Shown on model 257 with code 2U8 (refrigerant alternative)

1

Inerting system cartridge

2

Pipeline

3

Electrical connector

4

Nuts

5

Screw

P86.10-2434-06

Warning

Risk of injury during testing and repair operations related to pyrotechnical components

Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts.

AS91.00-Z-0008-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Notes on safety-relevant components

AH00.00-Z-0019-01A

Information, assessment and legal requirements when working with, handling and storing pyrotechnical components

AH91.00-Z-0000-10A

Remove/install

1

Deactivate anti-theft alarm system (ATA).

Model 257, 290
with code 2U8 (Alternative refrigerant)
with code 882 (Interior motion sensor)

2

Disconnect ground line from battery.

AR54.10-P-0003FR

3

Remove right front wheel.

AR40.10-P-1102A

4

Remove rear fender liner in right front fender.

AR88.10-P-1301FR

5

Open clamp (arrow A) of the piping (2) and remove piping (2) from the inerting system cartridge (1).

Installation: Install new clamp (arrow A) of the piping (2).

6

Disconnect cable tie (arrow B).

Installation: Install new cable tie (arrow B).

7

Disconnect electrical connector (3).

Removal lever

*203589043300

8

Remove screw (5).

9

Unscrew nuts (4) and remove inerting system cartridge (1) with the bracket.

Nut, holder for pressure medium reservoir to body

*BA86.10-P-1001-03E

10

Disconnect electrical connector from the alarm siren and unclip electric line from the bracket.

Model 257, 290
with code 2U8 (Alternative refrigerant)
with code 882 (Interior protection and tow-away protection)

11

Install in the reverse order.

Inerting

Number

Designation

Model 257

Model 290

BA86.10-P-1001-03E

Nut, holder for pressure medium reservoir to body

M6

Nm

8

8

Remove/install inertization cartridge

203 589 04 33 00

Removal lever