Shown on model 257 with code 2U8 (refrigerant alternative) |
1 | Inerting system cartridge |
2 | Pipeline |
3 | Electrical connector |
4 | Nuts |
5 | Screw |
P86.10-2434-06
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on safety-relevant components | |||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Deactivate anti-theft alarm system (ATA). | Model 257, 290 | |
2 | Disconnect ground line from battery. | ||
3 | Remove right front wheel. | ||
4 | Remove rear fender liner in right front fender. | ||
5 | Open clamp (arrow A) of the piping (2) and remove piping (2) from the inerting system cartridge (1). | Installation: Install new clamp (arrow A) of the piping (2). | |
6 | Disconnect cable tie (arrow B). | Installation: Install new cable tie (arrow B). | |
7 | Disconnect electrical connector (3). | Removal lever | |
8 | Remove screw (5). | ||
9 | Unscrew nuts (4) and remove inerting system cartridge (1) with the bracket. | Nut, holder for pressure medium reservoir to body | |
10 | Disconnect electrical connector from the alarm siren and unclip electric line from the bracket. | Model 257, 290 | |
11 | Install in the reverse order. |
203 589 04 33 00
Removal lever
Powiązane dokumenty
- ah0000z001901a Wskazówki dotyczące elementów wpływających na bezpieczeństwo
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar4010p1102a Demontaż i montaż kół
- ar5410p0003fr
- ar8810p1301fr
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi