AR86.10-P-0104A | Remove/install extinguishing agent tank squib | 30.4.09 |
MODEL 463.236 /236
with CODE (979) Special protection version
with CODE (ZS6) Special protection version FB6
with fire extinguishing system
MODEL 463.248 /248
with CODE (979) Special protection version
with CODE (ZS7) Special protection version FB7
with fire extinguishing system
P86.10-2105-11
Shown on extinguishing agent tank, left side
1 Extinguishing agent tank 1
R42 Extinguishing agent reservoir squib 1
R42x1 Extinguishing agent tank 1 squib electrical connector
| Remove/install | ||
| Notes on squib on extinguishing agent tank | ||
1 | Switch off ignition | ||
2 | Remove extinguishing agent tank cover | ||
3 | Disconnect electrical connector on extinguishing agent tank 1 squib (R42x1) or electrical connector on extinguishing agent tank 2 squib (R42/1x1) | When working on squibs always wear eye protection to avoid eye injuries. | |
To prevent the fire extinguishing system from being actuated, first disconnect electrical connector from extinguishing agent tank 1 squib (R42x1) or electrical connector from extinguishing agent tank 2 squib (R42/1x1) as first operation step. | |||
4 | Remove extinguishing agent tank 1 squib (R42) from extinguishing agent tank 1 (1) or extinguishing agent tank 2 squib (R42/1) from extinguishing agent tank 2 | When working on squibs always wear eye protection to avoid eye injuries. | |
Installation: Secure nuts with locking plates to prevent unscrewing by themselves. | |||
| |||
5 | Install in the reverse order | ||
| Checking | ||
6 | Check extinguishing agent tank 1 squib (R42) or extinguishing agent tank 2 squib (R42/1) | When working on squibs always wear eye protection to avoid eye injuries. |
Fire extinguishing system