ar8370s5653a

Removing and installing fuel strainer in intake connection of fuel metering pump

Typ ar · temat 83.70 · wersja 0100 · 1998-03-10

Dotyczy: MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater D5WS or B5WS

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.70 Ogrzewanie w czasie postoju, dodatkowe, nagrzewnica dodatkowa — Seria 638 (modele 0**, 1**, 2**)

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.25 Ogrzewanie postojowe/ ogrzewanie dodatkowe › 39.25.46 Pompa/ zbiornik — Seria 638 (modele 0**, 1**, 2**)

AR83.70-S-5653A

Removing and installing fuel strainer in intake connection of fuel metering pump

9.9.97

MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater
D5WS or B5WS

Removing and installing fuel strainer in intake connection of fuel metering pump

S83.70-2502-06

1 Fuel line

2 Hose clamp

3 Union nut

4 Fuel strainer

5 Clamp

6 Fuel metering pump

Removal, installation

1

Disconnect ground lead from battery

Installation: Set timer to current time (see Eberspächer operating instructions).

AR54.10-S-0005A

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation.

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel is toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

Fire, open lights and smoking prohibited. Avoid sparks.
Fill and store fuel only in containers intended for this purpose and marked accordingly.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

2

Attach clamp (5) to fuel line

*000589403700

3

Remove hose clamp (2) on fuel line (1)

Installation: Replace hose clamp.

4

Separate fuel line (1) from union nut (3)

Catch fuel running out in suitable vessel.

5

Unscrew union nut (3) from fuel metering pump (6)

To loosen union nut (3) hold fuel metering pump (6).

6

Remove fuel strainer (4) from fuel metering pump (6)

7

Install in opposite order

Removing and installing fuel strainer in intake connection of fuel metering pump

000 589 40 37 00

Clamp

Powiązane dokumenty