ar8370s5652b

Removing and installing fuel metering pump

Typ ar · temat 83.70 · wersja 0102 · 2010-09-15

Dotyczy: MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater D5WS or B5WS

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.70 Ogrzewanie w czasie postoju, dodatkowe, nagrzewnica dodatkowa — Seria 638 (modele 0**, 1**, 2**)

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.25 Ogrzewanie postojowe/ ogrzewanie dodatkowe › 39.25.46 Pompa/ zbiornik — Seria 638 (modele 0**, 1**, 2**)

AR83.70-S-5652B

Removing and installing fuel metering pump

7.9.10

MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater
D5WS or B5WS

Removing and installing fuel metering pump

S83.70-2501-06

1 Hose clamp

2 Fuel feed line

3 Fuel metering pump

4 Clamp

5 Fuel return line

6 Connector

7 Nut

8 Rubber mount

9 Holder

Removal, installation

1

Disconnect ground lead from battery

Installation: Set timer to current time (see Eberspächer operating instructions).

AR54.10-S-0005A

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation.

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel is toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

Fire, open lights and smoking prohibited. Avoid sparks.
Fill and store fuel only in containers intended for this purpose and marked accordingly.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

2

Disconnect connector (1) from fuel metering pump (3)

3

Attach clamps (4) on fuel lines (2, 5)

*000589403700

4

Remove fuel feed line (2) together with hose clamp (1)

Catch fuel running out in suitable vessel.

Installation: Replace hose clamp (1).

5

Remove fuel return line with hose
clamp (1)

Catch fuel running out in suitable vessel.

Installation: Replace hose clamp (1).

6

Unscrew nut (7) from rubber mount (8) on holder (9)

*BA83.70-N-1006-01A

7

Remove fuel metering pump (3) from rubber mount (8)

8

Install in opposite order

9

Check for proper function

AR83.70-S-5302-02A

Stationary heater

Number

Designation

Model
638

BA83.70-N-1006-01A

Rubber mount for fuel metering pump on holder

Nm

8

Removing and installing fuel metering pump

000 589 40 37 00