P83.70-5766-08
Shown on model 257 |
1 | Fuel hose | 3 | Bracket | |
2 | Electrical connector | Y23 | Stationary heater fuel pump |
Danger | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Danger | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed rooms or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
Notes on safety-relevant components | |||
| Remove/install | ||
1 | Release rear right underfloor paneling until the stationary heater fuel pump (Y23) is accessible. | ||
2 | Disconnect electrical connection (2). | ||
3 | Disconnect fuel hoses (1). | Clamp | |
4 | Remove fuel hoses (1) from stationary heater fuel pump (Y23). | Installation: Replace snap clamps. | |
Collect fuel which runs out in a suitable container. | |||
Pliers for click clamps | |||
5 | Unhook stationary heater fuel pump (Y23) from holders (3). | Installation: Observe direction of installation of stationary heater fuel pump (Y23). | |
6 | Install in the reverse order. |
000 589 40 37 00
Clamp
171 589 00 37 00
Pliers for click clamps