S83.30-4697-09
1 | Condenser | 4 | Bolts | 7 | Cable tie | ||
2 | Radiator | 5 | Screw | ||||
3 | Refrigerant lines | 6 | Electrical connector |
1 | Condenser |
5 | Screw |
7 | Cable tie |
8 | Retaining clamp |
9 | Guides |
S83.30-4698-06
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Drain air conditioning system | ||
2 | Remove upper front crossmember for hood catch | ||
3 | Remove refrigerant lines (3) | ||
| Compressor oils (specification 362.1) | ||
| |||
For this purpose, remove bolts (4). | |||
Installation: Replace sealing rings and moisten with compressor oil. | |||
Bolt, refrigerant line to condenser | |||
Record plug | |||
4 | Remove screw/bolt (5) | M6 | |
5 | Disconnect electrical connector (6) | ||
6 | Remove condenser (1) from cooler (2) | To do this, remove cable tie (7). | |
Installation: Install new cable tie (7). | |||
7 | Remove condenser (1) | | |
Press retaining clamp (8) inwards and remove condenser (1) upwards from guides (9). | |||
8 | Install in the reverse order |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8330s1760p
- ar8800s2303p
- as8300z000601a Zagrożenie zatruciem na skutek wdychania przegrzanych oparów czynnika chłodzącego R134a. Niebezpieczeństwo obrażeń w przypadku kontaktu płynnego czynnika chłodzącego R134a ze skórą i oczami oraz podczas obchodzenia się z
- bb0040p036201a