ar8330p5550fr

Check evaporator for leaks

Typ ar · temat 83.30 · wersja 0103 · 2019-07-03

Dotyczy: Model 257, 290

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.30 Układ klimatyzacji — Seria 257 · Seria 290

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.32 Obudowa/wymiennik ciepła/parownik/filtr — Seria 257 · Seria 290

AR83.30-P-5550FR

Check evaporator for leaks

02.07.2019

Model

257, 290

Check evaporator for leaks

1

Adapter

2

Sealing ring

3

Retaining plate

4

Evaporator intake connection

5

Evaporator pressure fitting

6

Sealing ring

P83.30-5140-11

Danger

Risk of explosion when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury due to bursting of high-pressure hoses.

Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only.

AS83.00-Z-0001-02A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Remove

1

Remove expansion valve.

AR83.30-P-5520MSA

Check

2

Install adapter (1) with adapter hose in place of expansion valve with new sealing rings (2, 6).

Use adapter hose from Adapter set (221 589 00 91 00).
Use adapter (1) from Adapter set (222 589 00 91 00).

Model 257Screw/bolt, adapter to retaining plate

*BA83.30-P-1009-01R

Model 290Screw/bolt, adapter to retaining plate

*BA83.30-P-1008-01S

Adapter kit

*221589009100

Adapter kit

*222589009100

3

Connect leak tester to adapter hose.

000 588 19 21 00 Leak tester

WS83.00-P-0035B

4

Fill evaporator with forming gas and check for leak tightness.

Pay attention to the leak tester operator's manual.
Do not fill evaporator with forming gas unless engine is cold.

Temperature changes during the pressure test (e.g. because of change in weather or cooling down of the engine compartment) can cause pressure fluctuations.
Consistent ambient conditions must therefore be strictly ensured.

Pressure drop in refrigerant circuit filled with test gas

*BE83.30-P-1001-04A

If a leakage is present,

replace evaporator.


AR83.30-P-5540FR

5

Disconnect leak tester unit from adapter hose.

6

Remove adapter hose and adapter (1).

Install

7

Install expansion valve with new sealing rings (2, 6).

AR83.30-P-5520MSA

Air conditioning

Number

Designation

Model 118, 164, 166, 167, 169, 171, 177, 190, 197, 199, 204, 205, 207, 209, 211, 212, 216, 218, 219, 221, 230, 238, 240, 245, 247, 251, 253, 257, 290, 292, 293
Model 213, 217, 222
except code 1U6 (R744 refrigerant)

BE83.30-P-1001-04A

Pressure drop in refrigerant circuit filled with test gas

Test pressure

bar

15

Test period

h

4

Permissible fluctuation of ambient temperature

°C

2

Pressure drop

bar

0

Air conditioning

Number

Designation

Model 290

BA83.30-P-1008-01S

Screw/bolt, adapter to retaining plate

Nm

7

Air conditioning

Number

Designation

Model 257

BA83.30-P-1009-01R

Screw/bolt, adapter to retaining plate

Nm

7

Check evaporator for leaks
Check evaporator for leaks

222 589 00 91 00

Adapter kit

221 589 00 91 00

Adapter kit

Powiązane dokumenty