P83.30-4533-08
1 | Valve element | 2 | Suction pipe | 3 | Pressure line |
| Remove/install | ||
Danger ! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Do not perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling refrigerant R134a | ||
1 | Drain air conditioning system | Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks | |
Installation: Evacuate air conditioning and then fill it. | |||
2 | Disconnect air conditioning service unit from diagnostic socket of suction line (2) and from diagnostic socket of pressure line (3) | ||
| 000 588 04 82 00 Air conditioning service unit | ||
3 | Remove valve insert (1) at diagnostic socket of pressure line (3) | In model 451.391/491 the valve element (1) is removed using a commercially available valve wrench for Schrader valves (connection size 4.5 mm). | |
Valve wrench | |||
4 | Install in the reverse order |
203 589 03 10 00
Valve wrench
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8330p1760mcc
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk
- ws8300p0031b