AR83.30-P-5535MCC | Remove/install intake manifold filling valve | 17.6.10 |
MODEL 451.3 /4 with CODE (I01) Air conditioning Plus
P83.30-4534-08
1 Valve element
3 Pressure line
2 Suction pipe
Modification notes
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling R134a refrigerant | Air conditioning with refrigerant R134a | |
1 | Discharge air conditioning system | Installation: Evacuate air conditioning and then fill. | |
2 | Disconnect air conditioner service unit from the service valve of the suction line (2) and the service valve of the pressure line (3) | Air conditioner service unit gotis://E_83_05.0 | |
3 | Remove valve element (1) on service valve of suction line (2) | In model 451.391/491, the valve insert (1) must be removed using a commercially available valve wrench for Schrader valves (connection width 4.5 mm). In model 451 (except 451.391/491), the valve wrench must be used. | |
Valve wrench | |||
4 | Install in the reverse order |
Valve wrench
203 589 03 10 00
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8330p1760mcc
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk