1

Diagnostic socket

2

Diagnostic socket

3

Air conditioning service unit connection

4

Air conditioning service unit connection

P83.30-3784-03

Danger !

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Do not perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

Draining

1

Remove luggage compartment pan

2

Unscrew plugs of diagnostic socket (1, 2)

3

Connect air conditioning service unit connection (3) to diagnostic socket (1) and air conditioning service unit connection (4) to diagnostic socket (2)

000 588 04 82 00 Air conditioning service unit

WS83.00-P-0031B

For all operation steps, the operator's manual for the air conditioning service unit must be followed.

4

Suction off refrigerant

Note down suctioned off oil fill capacity.

Evacuate

5

Install new desiccant cartridge

Only if refrigerant circuit has been opened.

AR83.30-P-6525RR

6

Clean refrigerant and evacuate air conditioning system using air conditioning service unit

Filling

7

Replace oil filling quantity noted down during evacuation of air conditioning system with new compressor oil and route back to refrigerant circuit


Pay attention to correct oil filling quantity.
Otherwise the refrigerant compressor may be damaged.

8

Fill air conditioning system using air conditioning service unit

Refrigerant

*BF83.30-P-1001-01C

9

Disconnect air conditioning service unit connection (4) from diagnostic socket (2) and air conditioning service unit connection (3) from diagnostic socket (1)

10

Screw plugs onto diagnostic socket (1, 2)

Check

11

Using air conditioning leak detector, inspect air conditioning for leaks at all points at which the system was opened

12

Install luggage compartment pan

Air conditioning

Number

Designation

Model 452.3/4

BF83.30-P-1001-01C

Refrigerant

Filling capacity

g

660 (-25)