1 | Refrigerant line |
2 | High-voltage connector |
D83.30-A026-76
D83.30-A022-79
1 | Refrigerant line | 4 | Screw | |
3 | Nut |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Empty refrigerant circuit. | ||
2 | Deenergize high-voltage on-board electrical system. | ||
3 | Remove electric line of high-voltage plug (2) from holder. | Installation: Check retaining clip. | |
If any is found, | |||
| |||
Replacing retaining clip. | |||
4 | Disconnect high-voltage plug (2) at refrigerant compressor. | ||
5 | Remove nut (3). | Nut, refrigerant line to refrigerant condenser for high-voltage battery cooling system | |
6 | Unscrew bolt (4). | Bolt, refrigerant line to refrigerant compressor | |
7 | Remove refrigerant line (1). | ||
| Compressor oils (specification 362.1) | ||
Seal openings on refrigerant condenser and on refrigerant compressor. | |||
Installation: Replace sealing rings and moisten with compressor oil. | |||
Record plug | |||
8 | Install in the reverse order. |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar4770d1000te
- ar8330d1760ts
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne
- as8300z000601a Zagrożenie zatruciem na skutek wdychania przegrzanych oparów czynnika chłodzącego R134a. Niebezpieczeństwo obrażeń w przypadku kontaktu płynnego czynnika chłodzącego R134a ze skórą i oczami oraz podczas obchodzenia się z
- bb0040p036201a