1 | Desiccant cartridge |
2 | Refrigerant condenser |
3 | Screw |
4 | Sealing rings |
S83.30-A005-82
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Remove refrigerant condenser (2). | ||
2 | Remove bolt (3) . | Screw, desiccant cartridge to refrigerant condenser for high-voltage battery cooling system | |
3 | Remove receiver drier (1) from refrigerant condenser (2). | ||
| Compressor oils (specification 362.1) | ||
Seal openings on receiver drier (1) and on refrigerant condenser (2). | |||
Installation: If the packaging is damaged or the stop plugs are missing on a new receiver drier (1), this new receiver drier (1) must not be installed. | |||
Assembly tool | |||
Record plug | |||
4 | Install in the reverse order. |
000 589 93 63 00
Assembly tool
129 589 00 91 00
Record plug