ar8330d5540na

Remove/install evaporator

Typ ar · temat 83.30 · wersja 0103 · 2003-09-22

Dotyczy: MODEL WD1, WD2, WD3, WD6, WD7 MODEL 903.67 with CODE (ZU7) National version for Canada MODEL 903.67 with CODE (ZU8) National version for USA MODEL 903.67 with CODE (ZU9) National version for Mexico MODELS XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (HH9) Automatic air conditioning "Tempmatic" MODELS 903.61 /66, 904.61 /66 with CODE (HH9) Automatic air conditioning "Tempmatic" with CODE (ZU7) National version for Canada MODELS 903.61 /66, 904.61 /66 with CODE (HH9

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.30 Układ klimatyzacji — Seria 903 (modele 61*, 62*, 66*, 67*) · Seria 904 (modele 61*, 62*, 66*)

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.32 Obudowa/wymiennik ciepła/parownik/filtr — Seria 903 (modele 61*, 62*, 66*, 67*) · Seria 904 (modele 61*, 62*, 66*)

AR83.30-D-5540NA

Remove/install evaporator

16.3.01

MODEL WD1, WD2, WD3, WD6, WD7

MODEL 903.67 with CODE (ZU7) National version for Canada

MODEL 903.67 with CODE (ZU8) National version for USA

MODEL 903.67 with CODE (ZU9) National version for Mexico

MODELS XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (HH9) Automatic air conditioning "Tempmatic"

MODELS 903.61 /66, 904.61 /66
with CODE (HH9) Automatic air conditioning "Tempmatic"
with CODE (ZU7) National version for Canada

MODELS 903.61 /66, 904.61 /66
with CODE (HH9) Automatic air conditioning "Tempmatic"
with CODE (ZU8) National version for USA

MODELS 903.61 /62 /66, 904.61 /62 /66
with CODE (HH9) Automatic air conditioning "Tempmatic"
with CODE (ZU9) National version for Mexico

Remove/Install

Danger!

Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning. Inhaling overheated refrigerant vapors may be toxic. Risk of injury. Contact with liquid refrigerant may result in injury to the skin and eyes.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged.

AS83.00-Z-0001-01A

The evaporator is part of the heater housing and can only be removed and installed or replaced together with it.

1

Discharge air conditioning system

Protect air conditioning circuit and components from moisture when carrying out repair work

All models fitted with air conditioning

AH83.30-N-0005-01A

2

Remove heater unit

AR83.25-D-1000NA

3

Install in the reverse order

4

Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak.