P83.25-A006-09
Shown with code 581 (Automatic air conditioning) |
1 | Plastic mount | 8 | Retaining tab | |
2 | Seal | 9 | Heat exchanger | |
3 | Coolant lines | 10 | Retaining clips | |
4 | Electrical connectors | 11 | AC housing | |
5 | Bolts | M2/8 | Left blending air flap actuator | |
6 | Bolts | M2/10 | Rear blend air flap actuator motor | |
7 | Screw |
| Remove/install | ||
1 | Remove air conditioner housing (11). | ||
2 | Detach plastic holder (1) and remove seal (2) from coolant lines (3). | ||
3 | Disconnect electrical connector (4) from left air mixing flap actuator motor (M2/8) and place electrical wiring harness to one side. | ||
4 | Disconnect electrical connector (4) from rear air mixing flap actuator motor (M2/10) and place electrical wiring harness to one side. | Model 293 | |
5 | Remove screws (5) and remove actuator unit with rear air mixing flap actuator motor (M2/10). | Model 293 | |
6 | Remove screws (6) and remove left air mixing flap actuator motor (M2/8). | ||
7 | Remove bolts_(7). | ||
8 | Release retaining tabs (8) and remove heat exchanger (9). | ||
9 | Release retaining clamps (10) and remove coolant lines (3) from heat exchanger (9). | Installation: | |
10 | Install in the reverse order. |