P83.10-2973-09
1 | Electrical connector | 5 | AC housing | 9 | Bolts | ||
2 | Air duct segment | 6 | Electrical connector | M2/14 | Defroster/footwell/center air vent flap actuator motor | ||
3 | Electrical line | 7 | Bolts | ||||
4 | Kinematics | 8 | Retaining lug |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on safety-relevant components | |||
| Remove/install | ||
1 | Connect vehicle diagnosis system and move defroster/footwell/center air vent flap actuator motor (M2/14) into assembly position. | ||
| |||
The defroster/footwell/center air vent flap actuator motor (M2/14) must be at 100% for 1 zone air conditioning system. | |||
For 2 zone air conditioning system, the defroster/footwell/center air vent flap actuator motor (M2/14) must be at 86.1%. | |||
2 | Switch off ignition and store transmitter key outside of transmitter range (min. 2 m). | ||
3 | Remove glove box. | ||
4 | Release electrical connector(1) and disconnect. | ||
5 | Remove air duct segment (2). | ||
6 | Loosen electrical line (3) from kinematics (4) and air conditioner housing (5). | ||
7 | Release and disconnect electrical connectors (6). | ||
8 | Unscrew screws (7). | ||
9 | Press retaining lugs (8) and remove kinematics (4) from air conditioner housing (5). | Installation: Make sure that the retaining lugs (8) are correctly engaged. | |
10 | Remove screws/bolts (9). | ||
11 | Remove defroster/footwell/center air vent flap actuator motor (M2/14). | ||
12 | Install in the reverse order. | ||
Concluding tasks | |||
13 | Connect vehicle diagnosis system, normalize defroster/footwell/center air vent flap actuator motor (M2/14) and clear fault memory. | ||
|