ar8310p2037mfa

Remove/install actuator motor for flap of defroster/footwell/center air vents

Typ ar · temat 83.10 · wersja 0102 · 2019-02-21

Dotyczy: Model 118, 177, 247

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.10 Wentylacja — Seria 118 · Seria 177 · Seria 247

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.30 Silnik dmuchawy/ siłownik — Seria 118 · Seria 177 · Seria 247

AR83.10-P-2037MFA

Remove/install actuator motor for flap of defroster/footwell/center air vents

20.02.2019

Model

118, 177, 247

Remove/install actuator motor for flap of defroster/footwell/center air vents

P83.10-2973-09

1

Electrical connector

5

AC housing

9

Bolts

2

Air duct segment

6

Electrical connector

M2/14

Defroster/footwell/center air vent flap actuator motor

3

Electrical line

7

Bolts

4

Kinematics

8

Retaining lug

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Notes on safety-relevant components

AH00.00-Z-0019-01A

Remove/install

1

Connect vehicle diagnosis system and move defroster/footwell/center air vent flap actuator motor (M2/14) into assembly position.

AD00.00-P-2000-06MFA

The defroster/footwell/center air vent flap actuator motor (M2/14) must be at 100% for 1 zone air conditioning system.

For 2 zone air conditioning system, the defroster/footwell/center air vent flap actuator motor (M2/14) must be at 86.1%.

2

Switch off ignition and store transmitter key outside of transmitter range (min. 2 m).

3

Remove glove box.

AR68.10-P-1400MFA

4

Release electrical connector(1) and disconnect.

5

Remove air duct segment (2).

6

Loosen electrical line (3) from kinematics (4) and air conditioner housing (5).

7

Release and disconnect electrical connectors (6).

8

Unscrew screws (7).

9

Press retaining lugs (8) and remove kinematics (4) from air conditioner housing (5).

Installation: Make sure that the retaining lugs (8) are correctly engaged.

10

Remove screws/bolts (9).

11

Remove defroster/footwell/center air vent flap actuator motor (M2/14).

12

Install in the reverse order.

Concluding tasks

13

Connect vehicle diagnosis system, normalize defroster/footwell/center air vent flap actuator motor (M2/14) and clear fault memory.

AD00.00-P-2000-06MFA