P83.10-2801-06
1 Bolts
2 Electrical connector
A32 AC housing
M2/6 Left blend air flap actuator motor (for code (581) Comfort automatic air conditioning)
M2/14 Blend air flap actuator motor
(without code (581) Comfort automatic air conditioning)
| Remove/install | ||
1 | Remove cover below left of instrument panel | ||
2 | Unscrew bolts (1) and remove left blend air flap actuator motor (M2/6) or blend air flap actuator motor (M2/14) from air conditioner housing (A32) | Installation: Install left blend air flap actuator motor (M2/6) or blend air flap actuator motor (M2/14) on guide pin (arrow) on air conditioner housing (A32). | |
3 | Disconnect electrical connector (2) from left blend air flap actuator motor (M2/6) or blend air flap actuator motor (M2/14) | ||
4 | Install in the reverse order | ||
5 | Connect Star Diagnosis and normalize left blend air flap actuator motor (M2/6) or blend air flap actuator motor (M2/14) |