P83.10-2806-07
Illustrated on the removed air conditioner housing
1 Bolts
2 Electrical connector
M2/22 Center air outlet flap actuator motor
A32 AC housing
| Remove/install | ||
1 | Detach crossmember below instrument panel until center air vent flap actuator motor (M2/22) can be removed | ||
2 | Unscrew bolts (1) and remove center air vent flap actuator motor (M2/22) from air conditioner housing (A32) | Installation: Install center air vent flap actuator motor (M2/22) on guide pin (arrow) on air conditioner housing (A32) | |
3 | Disconnect electrical connector (2) from center air vent flap actuator motor (M2/22) | ||
4 | Install in the reverse order | ||
5 | Connect Star Diagnosis and normalize center air vent flap actuator motor (M2/22) |