AR83.10-P-2001R | Remove/install actuator motor for fresh and recirculated air flaps | 20.12.05 |
MODEL 230.4
P83.10-2205-06
Illustrated on the removed A/C housing
1 Electrical connector
M16/21 Fresh air/air recirculation flap actuator motor
| Remove/install | ||
1 | Remove instrument panel | ||
2 | Remove front passenger airbag unit | ||
3 | Disconnect electrical connector (1) from fresh air/recirculated air flap actuator motor (M16/21) | ||
4 | Remove fresh air/air recirculation flap actuator motor (M16/21) from AC housing | ||
5 | Install in the reverse order | ||
6 | Read out fault memory, delete if necessary and normalize fresh air/air recirculation flap actuator motor (M16/21) | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system |
Commercially available tools
Powiązane dokumenty
- ad0000p200004a Podłączanie STAR DIAGNOSIS, odczytywanie pamięci usterek
- ad0000p200004a
- ar6810p1000r
- ar9160p0680r