AR83.10-P-2001MCC | Remove/install actuator motor for fresh and recirculated air flaps | 23.4.07 |
MODEL 451.3 /4 with CODE (I01) Air conditioning Plus
P83.10-2620-04
1 Electrical connector
2 Bolts
M39 Air recirculation flap actuator motor
| Remove/install | ||
1 | Remove top part of instrument panel | ||
2 | Disconnect electrical connector (1) from air recirculation flap actuator motor (M39) | ||
3 | Remove bolts (2) and remove air recirculation flap actuator motor (M39) | ||
4 | Install in the reverse order | ||
5 | Carry out function test on air recirculation flap actuator motor (M39) |