ar8310p0100sn

Remove/install air recirculation unit

Typ ar · temat 83.10 · wersja 0101 · 2005-09-08

Dotyczy: MODEL 450.3## /4## (except 450.418) 2# except CODE (I01) Air conditioning Plus (with outside temperature indicator) (FFO) except CODE (I29) Air conditioning Plus (with combination filter and outside temperature indicator), smart & passion

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.10 Wentylacja — Seria 450 (modele 3**, 400, 401, 402, 403, 414, 432, 433, 441, 442, 443, 452)

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.32 Obudowa/wymiennik ciepła/parownik/filtr — Seria 450 (modele 3**, 400, 401, 402, 403, 414, 432, 433, 441, 442, 443, 452)

AR83.10-P-0100SN

Remove/install air recirculation unit

25.9.02

MODEL 450.3## /4## (except 450.418) 2#
except CODE (I01) Air conditioning Plus (with outside temperature indicator) (FFO)
except CODE (I29) Air conditioning Plus (with combination filter and outside temperature indicator), smart & passion

Remove/install air recirculation unit

P83.10-2344-09

Shown on model 450.3

1 Air recirculation box

2 Tie strap

3 Horizontal strut

6 Nut

7 Passenger-side footrest

4 Bolts

5 Crossmember

Remove/install air recirculation unit

P83.10-2345-06

1 Air recirculation box

8 Recirculated air cable

9 Nut

10 Nuts

11 Catch

12 Lever

Remove/install

1

Remove front floor covering

AR68.20-P-2040SM

2

Remove right sound converter box

AR82.60-P-1100SN

3

Remove electronic accelerator pedal

AR30.20-P-2000SN

4

Remove cable ties (2) at horizontal strut (3)

5

Remove bolts (4) at crossmember (5)

6

Remove nuts (6) from firewall and remove horizontal strut (3)

7

Remove passenger-side footrest (7)

AR68.30-P-1340SM

8

Detach recirculated air cable (8) from air recirculation unit (1)

Installation: Insert recirculated air cable (8) into catch (11) and attach to lever (12).

Adjust recirculated air cable (8):

Detach recirculated air cable (8) out of catch (11) on lever (12) on air recirculation unit (1).

Press heater/ventilation control unit lever all the way up and hold.

Press lever (12) on air recirculation unit (1) all the way to the left and lock recirculated air cable (8) cover.

9

Remove nut (9) at top of firewall

10

Remove nuts (10) from bottom of firewall and remove air recirculation unit (1)

11

Install in the reverse order

12

Carry out function test

Powiązane dokumenty