ar8310d2026ts

Remove/install blend air flap actuator motor

Typ ar · temat 83.10 · wersja 0200 · 2019-11-14

Dotyczy: Model 907, 910

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.10 Wentylacja — Seria 907 · Seria 910

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.30 Silnik dmuchawy/ siłownik — Seria 907 · Seria 910

AR83.10-D-2026TS

Remove/install blend air flap actuator motor

31.10.2019

Model

907, 910

Modification notes

29.10.2019

"Teach in and normalize actuator motor (1) and erase fault memory using vehicle diagnosis system", added.

Operation step 10

Remove/install blend air flap actuator motor

D83.10-1201-09

1

Actuator motor

3

Electrical connector

2

Bolts

4

Driver

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Topical note

Notes on carrying out repair work in the vehicle interior

AH68.00-N-0001-01S

Remove

1

Remove blower motor.

AR83.25-D-1200TS

2

Remove screw/bolts (2) .

3

Remove actuator motor (1) until the electrical connector (3) is accessible.

The air mixing flap drops to its end position when the actuator motor (1) is removed.

4

Disconnect electrical connector (3) and remove actuator motor (1).

Install

5

Connect electrical connector (3) at actuator motor (1).

6

Position actuator motor (1) through slight pressure at driver (4).

7

Switch on ignition and adjust the temperature on the air conditioning control panel.

The actuator motor (1) can be moved completely onto the driver (4) as soon as the truncation (arrow B) of the actuator motor (1) is aligned with the truncation (arrow A) of the driver (4).

8

Screw in bolts (2).

9

Install blower motor.

AR83.25-D-1200TS

10

Teach in and normalize actuator motor (1) and erase fault memory using vehicle diagnosis system.

AD00.00-D-2000-06TS

Check

11

Carry out function test of actuator motor (1).