1 | Cover |
2 | Cover |
3 | Electrical connector |
4 | Retaining clamp |
B38/2 | Rain/light sensor with additional functions |
P82.30-3134-06
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Commission rain and light sensor with additional functions (B38/2). | When replacing rain/light sensor with additional functions (B38/2). | |
| |||
2 | Switch off ignition and store transmitter key outside of transmitter range (at least 2 m). | ||
3 | Unclip and remove cover (1). | Long wedge | |
4 | Unclip and remove cover (2). | Long wedge | |
5 | Unhook retaining clamps (4) on both sides of rain and light sensor with additional functions (B38/2). | ||
6 | Remove rain and light sensor with additional functions (B38/2) and disconnect electrical connector (3). | | |
7 | Install in the reverse order. |
115 589 03 59 00