Remove/install bulbs of headlamp unit

Typ ar · temat 82.10 · wersja 0102 · 2019-12-05

Dotyczy: Model 170 with code 612 (Xenon headlamp unit)

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 82 Układ elektryczny, nadwozie › 82.10 Oświetlenie zewnętrzne — Seria 170

EinPAS 30 Instalacja oświetleniowa › 30.15 Oświetlenie zewnętrzne › 30.15.40 Lampa przednia — Seria 170

AR82.10-P-1201CA

Remove/install bulbs of headlamp unit

19.11.2019

Model

170

with code 612 (Xenon headlamp unit)

Remove/install bulbs of headlamp unit

1

Central connector

2

Bolts

3

Retaining plate

4

Xenon bulb D2R

E1

Left lamp unit

E2

Right lamp unit

P82.10-2572-06

Remove/install

Danger

Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)

Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.

AS00.00-Z-0035-01A

Danger

Risk of explosion/risk of fire caused by highly flammable materials in the vicinity of damaged xenon bulbs. Risk of injury caused by UV light, hot components on xenon headlamps and glass splinters produced by bursting xenon bulbs. Risk of poisoning caused by inhalation of mercury vapors and by swallowing of/skin contact with toxic salts and mercury compounds.

Do not touch parts conducting high voltage. Persons with active electronic implants (e.g. cardiac pacemakers) must never work on xenon headlamps. Switch off the entire lighting system. Wear insulated safety shoes, safety glasses and protective gloves. Remove highly inflammable materials from the danger zone. Ensure sufficient ventilation in the working area.

AS82.10-Z-0001-01A

1

Remove lamp unit


Up to 31.07.99

AR82.10-P-4730EDD

2

Remove housing cover

3

Remove central connector (1)

4

Undo screws (2) and remove retaining plate (3)

The retaining plate (3) is unlocked by turning counterclockwise.

5

Carefully remove xenon bulb D2R (4)


Do not touch the glass of the bulbs with bare fingers,
use a grease-free, soft cloth. Ensure correct installation position.

6

Install in the reverse order