Prepare window frame paneling (1)
S72.20-4690-09
1 | Window frame paneling | 1.3 | Pin | C | 10 mm | ||
1.1 | Ø 8.8 mm hole for curtain rod | A | 295 mm | D | 37 mm | ||
1.2 | Ø 4.2 mm for pin | B | 230 mm |
1 | Drill Ø 8.8 mm hole for curtain rail (1.1) in window frame paneling (1) as shown. |
Dimensions (A, C) measured at 90° angle from outer edges of window frame paneling (1). A flexible measuring tape is laid directly on the window frame paneling (1). |
2 | Drill Ø 4.2 mm holes for pins (1.2) in window frame paneling (1) as shown. |
Dimensions (B, D) measured at 90° angle from outer edges of window frame paneling (1). A flexible measuring tape is laid directly on the window frame paneling (1). |
3 | Fasten pins (1.3) on window frame paneling (1) with blind rivet. |
Prepare liftgate paneling (2)
S72.20-4691-09
2 | Bottom liftgate paneling | E | 65 mm | H | 45 mm | ||
2.1 | Ø 4.2 mm for pin | F | 110 mm | ||||
2.2 | Pin | G | 60 mm |
4 | Drill Ø 4.2 mm holes for pins (2.1) in liftgate paneling (2) as shown. |
Dimensions (G, H) measured at 90° angle from outer edge of liftgate paneling (2). |
5 | Fasten pins (2.2) to liftgate paneling (2) with blind rivet. |